ePED® EMERGENCY OPEN module
Standard for 55 mm modules
Product description
Single module in Hi-O bus technology with optimized operating concept. To control locking/unlocking, temporary unlocking, alarm acknowledgement through a potencial-free contact such as card reader, door code systems or others. Or to conventionally control through key switch, tested in compliace with EltVTR.
Overview of Advantages
- Emergency button lights up; features reusable, non-detachable, shatterproof protective cover
- Integrated visual door status indicator with high-performance LEDs (green / red / yellow) signalling unlocked / locked / alarm status
- Emergency button sign (arrow pointing downwards)
- Acoustic signal and tampering contact
- Adjustable time period for delayed permanent release, temporary release, pre-alarm, alarm interval, guidance signal
- Monitoring of time door is open in the case of temporary unlocking
- With two inputs featuring adjustable parameters for: control via an external operating element or; temporary release via AC system or; emergency locking via fire alarm system or; unlocking via switching timer.
- With a relay output featuring adjustable parameters for: door locked/unlocked, door open/closed, common alarm, individual alarm or activation of electric strike/ motorised lock/ revolving door drive/ arrestor system.
- System connector for setting parameters with ePED® service interface and software for MS Windows
- Connections: SYSCON-4: Hi-O bus; SYSCON-5: operating unit, screw/ plug-in terminals
Rated current consumption | 25 mA |
Current consumption 24 V DC | 120 mA |
Control function | Yes, Hi-O technology |
Operating and display function | Yes, integrated |
Connection | 4-wire bus; SYSCON 4 |
Emergency button | Yes, latching |
Control element | No, external operating unit required |
Initial configuration | With ePED® service interface and software for MS Windows |
Required power supply | 12 V (-15 %) to 24 V (+15 %) DC SELV; optimal voltage = 24 V DC |
Operating temperature range | -10 °C – +55 °C |
Area of application | For indoor use |
Class of protection | IP30 (wenn vollständig montiert) |
Installation | To install flush mounted switch box, 62 mm deep, frame or surface housing necessary |
Sabotage switch | Yes |
Inputs | 2 |
Outputs | 1 x 30 V / 1 A switchover contact |
Amount of bus addresses | 2 |
Escape door terminal with bi-directional escape route | Yes |
Certified in compliance with | EltVTR; DIN EN 13637:2015 |
Control | Yes, Hi-O technology |
Function indicator | Yes, integrated |