ePED® panic touch bar, controlled on display terminal N3722
Product description
For use in conjunction with a permitted lock. As a panic touch bar and to secure the active leaf as an electrically controlled emergency exit door system.
Use with and without release delay, with four-wire bus cabling in Hi-O technology.
Electrically controlled touch bar panic function to secure the panic lock against misuse.
Emergency open module to control and monitor electrical locking elements approved for escape and rescue routes.
The release delay is tested as per the requirements specified in EN 13637:2015 (electrically controlled exit systems for use on escape routes) as per EN 61508 Safety Integrity Level 2 (SIL2).
Current building codes state that an approval from the relevant building inspectorate is mandatory for applications with a release delay.
Overview of Advantages
- panic touch bar as per EN 1125
- Electrically controlled panic function
- Emergency door release by pushing the display unit
- Optional emergency open activation by pressing the panic touch bar
- Pictogram with situational display of the operating status
- Acoustic signaling of alarms or disruptions with the orientation signal function
- Display of the optional time delay
- Authorised operation with authorisation code on touch screen
- Configuration of the escape door system
- Extension and external activation via the Hi-O bus
Note
- ePED touch bars are custom-manufactured for the desired base profile length. Dimensions cannot be changed at a later stage.
- As a general rule, such custom-made products cannot be returned or cancelled.
- Indicate the length of the base profile with a tolerance of ±1 mm when placing orders.
Current consumption 24 V DC | 550 mA |
Control function | Yes, Hi-O technology |
Panic function | Gesteuert |
Operating and display function | Yes, integrated |
Power supply | No, external power supply is necessary |
Connection | 4-wire bus |
Release delay | Yes (optional) |
Display of down counter | Yes |
Illuminated pictogram | Yes, by the integrated touch display |
Emergency Push Button | Yes, by pressing the display unit or panic touch bar |
Control element | Code and function surface on touch display |
Initial configuration | Configuration by integrated touch display |
Required power supply | 24 V (±10 %) DC SELV |
Operating temperature range | -10 °C – +55 °C |
Relative humidity | < 95% (non-condensing) |
Area of application | For indoor use |
Class of protection | IP30 (if completely installed) |
Mounting dimensions | 900-1430 mm |
Base profile length | 850-1380 mm |
Total length | Base profile + 80.5 mm |
Backset | ≥ 35 mm |
Installation height | 100 mm |
DIN-direction | Universal |
Push bar profile | Stainless steel |
Sabotage switch | Yes |
Inputs | None; using Hi-O bus extension |
Outputs | None; using Hi-O bus extension |
Amount of bus addresses | 3 |
Expandable | Yes, using Hi-O bus |
Certified in compliance with | EltVTR; DIN EN 13637:2015 |
Order number | Description |
---|---|
N372200xxxx0000 | Controlled with display terminal, language: German |
N372200xxxxGB00 | Controlled with display terminal, language: English |